| Sign In | Join Free | My entremaqueros.com | 
              
  | 
      
Brand Name : Coolmay
Model Number : EX3G-43H-44MT
Certification : CE
Place of Origin : Shenzhen
MOQ : 1 pcs
Price : Negotiable
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 100,000 pcs per month
Delivery Time : 3-7 work days
Packaging Details : Packed with standard carton box
Dimension : 134*102*32mm
Resolution : 480*272 pixels
ROM : 128MB
CPU : ARM9 core 400MHz
DI/DO : 12DI/12DO
Analog I/O : (optional) Max 4AI/2AO
HMI port : RS232 port
PLC port : Mini type B USB port
Integrated HMI PLC DIN-Rail Install Passive NPN Input RS485 Optional
Advantage:
◆ Upper computer programming software compatible with Works 2/GX Developer8.86 (supports Ladder diagram and SFC language, does not support structured programming/labels).
◆ Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.
◆ Clock supported, rechargeable battery adopted.
◆ Support Mitsubishi programming port protocol/Modbus protocol/Rs protocol/BD board protocol,
PLC communication with each other and other devices is easily achieved.
◆ High speed counter.regularly single phase 6 channels 60KHz/ AB(Z) Phase 2 channels 60KHz + AB phase 1 channel 10KHz.
◆ Support multiple types analog individually or mixed ones for analog output and input.
◆ Convenient for wiring, adopting 3.81mm pluggable terminals.
◆ Easy installation. DIN-Rail (35mm width) installation and fixed hole installation.Flexible, can be customized accordingly.
◆ PLC Software is compatible to Mitsubishi, HMI use Coolmay programming software.
Parameter:
|  			 Display  |  			 			 Dimension  |  			 			 134*102*32mm  |  		
|  			 Resolution  |  			 			 480*272 pixels  |  		|
|  			 Type  |  			 			 4.3” TFT  |  		|
|  			 Features  |  			 			 Support interrupt, linear arc interpolation, PID auto-tuning. 32K program capacity, 32K retentive register  |  		|
|  			 Memory  |  			 			 RAM  |  			 			 64MB  |  		
|  			 ROM  |  			 			 128MB  |  		|
|  			 CPU  |  			 			 ARM9 core 400MHz  |  		|
|  			 I/O  |  			 			 DI/DO  |  			 			 12DI/12DO  |  		
|  			 Input: Passive NPN, public terminal isolated Transistor output: Low level NPN, COM connect to negative; Relay output: Normally open dry contact  |  		||
|  			 DO type and load  |  			 			 Relay MR/MOS tube, MOS tube: 2A/point, 4A/4 point COM, 5A/12 point COM; MR: 2A/point, 5A/12 point COM.  |  		|
|  			 Analog I/O (optional)  |  			 			 Max 4AI/2AO  |  		|
|  			 AI type (optional)  |  			 			 Type E/E_/K/K_/S/S_/T/T_/J/J_ thermocouple/ PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/ 0~10V/ 0~5V/ 0~20mA/ 4~20mA/ mixed  |  		|
|  			 AO type (optional)  |  			 			 0~10V /0~5V/ 0~20mA/ 4~20mA/ mixed  |  		|
|  			 High-speed function  |  			 			 High-speed counting  |  			 			 6 channels single-phase 60KHz, or 2 channels AB (Z) phase 60KHz + 1 channel AB phase 10KHz  |  		
|  			 High-speed pulse  |  			 			 8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz High-speed counting + high-speed pulse < 480KHz  |  		|
|  			 Connection  |  			 			 HMI  |  			 			 1 HMI download port  |  		
|  			 1 RS232 port  |  		||
|  			 PLC  |  			 			 1 Mini type B USB port, 1 RS232 port (Program port,also can be used as COM port)  |  		|
|  			 1 RS485 or 2 RS485 COM ports (one is changed from the default RS232 port)  |  		||
|  			 Software  |  			 			 HMI  |  			 			 CoolMay HMI programming software  |  		
|  			 PLC  |  			 			 Compatible with Mitsubishi GX Developer8.86 and GX WORKS 2  |  		
PLC Programming notice
The PLC is compatible with GX 8.86/Works 2 and below. If you use other versions of the software, incompatibility may occur.
When the PLC program is downloaded, there is a prompt error: Cannot specify the com port,
GX 8.86 software: Online - Transfer settings change com port;
Works 2: All targets - Change the com port in all connected targets;
If communication error occurs, cable is abnormal If prompted, remove it by powering off, detecting the cable, detecting whether the power is normal, or replacing the computer.
In the Works 2 software version, choose the figure : (Note: the label is forbidden)

Introduction of each interface and indicator:
POWER: Power indicator, connected to the power light
RUN: PLC running status indicator. This light is on when the PLC is running.
COM: touch screen and PLC communication status indicator, when the two communicate, the light is on
Power terminal: The positive and negative terminals of the DC24V switching power supply are respectively connected to the DC24V and 0V of the power supply terminal.
PLC programming port: two PLC programming ports (MiniB type usb port / RS232), PLC program can be downloaded through 232 programming line or USB cable download
Touch screen programming port: download touch screen configuration program
USB interface: mainly can be directly inserted into the U disk of the file system FAT 32, can also be inserted into the mouse.
| 
                                             | 
                
                        DIN Rail Integrated HMI PLC Passive NPN Input RS485 PLC HMI Panel Images |